Sitemap: Home arrow Chorma Forum

ngimg0






Lost Password?
No account yet? Register
 
 
 

 
Chroma Forum

This is open to ALL end users of systems - simply register to post 'New Topics' or 'Reply current posts' register here for immediate access
Register Here.

Chroma Forum  


Analysing Resins by Static Headspace GC - 2005/11/28 18:33 Ian is correct on all counts. When I saw HS, I assumed you were only interested in the resin's volatile components. That was my interest in the hot melt glue resin. If the volatile components were not the same batch to batch, the glue would not harden quickly enough to bond the case flaps. I assumed you were interested in the ink resin's volatile components for drying effect. If that is the case, a double run might be the best way to go. The first, at low temperature, 100C, with static head pressure. The second vial I would put in a vaccuum oven at 60C before applying the cap. I would then place it in the HS unit at perhaps 200C and sample with the assistance of nitrogen pressurization of the vial. If you are interested in the resins rather than the volatile components, HS/GC is not the way to go. HPLC might be a another choice to GC. Depending on the resin's composition one of the many HPLC systems should work, normal phase, reverse phase, size exclusion, ion exclusion, etc. Somthing is sure to work. I am positiive that what you need is already in use somewhere. Hopefully, you will not have to re-invent the wheel to complete your project.
  | | The administrator has disabled public write access.

      Topics Author Date
    emo
Analysing Resins by Static Headspace GC
admin 2005/11/28 18:30
    thread link
thread linkthread link Analysing Resins by Static Headspace GC
admin 2005/11/28 18:30
    thread link
thread linkthread linkthread link Analysing Resins by Static Headspace GC
admin 2005/11/28 18:31
    thread link
thread linkthread linkthread linkthread link Analysing Resins by Static Headspace GC
admin 2005/11/28 18:32
    thread link
thread linkthread linkthread linkthread linkthread link Analysing Resins by Static Headspace GC
admin 2005/11/28 18:32
    thread link
thread linkthread linkthread linkthread linkthread linkthread link Analysing Resins by Static Headspace GC
admin 2005/11/28 18:33

© 2009 LC Services
HPLC l Service Contracts l Gas Chromatography l Mass Spectrometry l Qualification l Breakdowns l Supported Models l Company Overview
Chorma Forum l Parts and Accessories l Refurbished Equipment l HPLC Training l Sitemap l Contact Us

Registered office: First floor, 5 Doolittle Yard, Froghall Road. Ampthill, Beds. MK45 2NW
Registered in England & Wales No.3219349 - VAT Number GB705847031
BS EN ISO 9001: 2000 Registered Cert No. 18198 / UKAS Quality Management